Do you have any questions about our products? Our experts will be glad to assist you! Just give us a call +45 96 35 06 06

Product Comparison for 2 products

 Forward
Article
Technical Data
Cable length:
Side 1
Tightening torque:
Mounting method:
Family construction form:
Thread:
suitable for corrugated tube (internal Ø):
Cable outlet:
Coding:
Material:
No. of poles:
Width across flats:
Degree of protection (EN IEC 60529):
Side 2
Tightening torque:
Mounting method:
Family construction form:
Thread:
suitable for corrugated tube (internal Ø):
Cable outlet:
Coding:
Material:
No. of poles:
Width across flats:
Degree of protection (EN IEC 60529):
Electrical data | Supply
Operating voltage AC max.:
Operating voltage DC max.:
Operating voltage AC (UL-listed):
Operating voltage DC (UL-listed):
Current operating per contact max.:
Installation | Connection
Mounting set:
Device protection | Electrical
Degree of protection (EN IEC 60529):
Additional condition protection degree:
Pollution Degree:
Rated surge voltage:
Material group (IEC 60664-1):
Mechanical data | Material data
Coating locking:
Coating of fitting:
Locking material:
Material screw connection:
Mechanical data | Mounting data
Mounting method:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Conformity
Product standard:
Cable data
Cable
wire arrangement:
General data | Cable
Cable identification:
Cable Type:
Function cable:
Jacket Color:
Type of Certificate:
STOOW style jacket:
Structure | Cable
Stranding cable total:
Amount stranding:
Stranding:
Amount stranding (type 4):
Stranding (type 4):
Stranding factor min. (type 4):
Stranding factor max. (type 4):
Amount stranding (type 5):
Stranding (type 5):
Stranding factor min. (type 5):
Stranding factor max. (type 5):
Filler:
wire arrangement:
Mechanical data | Cable
Cable length max.:
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Ingredient freeness wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Conductor type (wire):
Ingredient freeness wire insulation (Data):
Material wire insulation (Power):
Outer diameter wire insulation (Power):
Tolerance outer diameter wire insulation (Power):
Shore hardness wire insulation (Power):
Material properties wire insulation (Power):
Ingredient freeness wire insulation (Power):
Resistances wire insulation (Power):
Printing colour wire insulation (Power):
Printing spacing wire insulation (Power):
Amount wires (Power):
Amount strands wire (Power):
Diameter of single wires (Power):
Wire conductor cross section (Power):
Material conductor wire (Power):
Conductor type wire (Power):
Electrical function wire (Power):
Traversing distance (C-track):
Electrical data | Cable
Nominal voltage AC max.:
Max. rated voltage (conductor - conductor):
Max. rated voltage (conductor - ground):
Current load capacity (standard):
Current load capacity min. wire:
Current load capacity min. Wire (Data):
Current carrying capacity min. wire (Power):
Electrical resistance line constant wire:
Electrical resistance coating wire (Power):
AC withstand voltage (wire - wire):
Electrical capacity line constant (wire - wire):
Electrical capacity line constant (wire - shield):
Power frequency withstand voltage (wire - jacket):
Isolation resistance:
Loop resistance:
Max. rated voltage power (conductor - ground):
Max. rated voltage power (conductor - conductor):
Nominal voltage power AC max.:
Electrical capacity line constant (wire - shield) (power):
Electrical capacity line constant (wire - wire) (power):
Electric capacitance (power):
AC withstand voltage power (wire - shield):
Power frequency withstand voltage power (wire - jacket):
AC withstand voltage power (wire - wire):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (fixed):
Bending radius (dynamic):
No. of bending cycles (C-track):
Traversing distance (C-track):
Travel speed (C-track):
No. of torsion cycles:
Torsion stress:
Torsion speed:
Classifications
ECLASS-6.0:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Commercial data
Packaging unit:
customs tariff number:
GTIN:
Approvals
Certificates
Certificate
Certificate
Certificate
Certificate
Certificate
Certificate
Move
M12 male 0° / M12 female 0° A-cod. M12 male 0° / M12 female 0° A-cod.
PUR 5x0.34 bk UL/CSA+drag ch. 1.5m
Weight: 0.081 kg
Art.No.: 7000-40041-7320150

Available
Move
M12 male 0° / M12 female 0° A-cod. M12 male 0° / M12 female 0° A-cod.
PUR 5x0.34 bk UL/CSA+drag ch. 2m
Weight: 0.101 kg
Art.No.: 7000-40041-7320200

Available
1,5 m
2 m
0,6 Nm
0,6 Nm
inserted, screwed
inserted, screwed
M12
M12
M12 x 1
M12 x 1
10 mm
10 mm
straight
straight
A
A
PUR
PUR
5
5
SW13
SW13
IP65, IP66K, IP67
IP65, IP66K, IP67
0,6 Nm
0,6 Nm
inserted, screwed
inserted, screwed
M12
M12
M12 x 1
M12 x 1
10 mm
10 mm
straight
straight
A
A
PUR
PUR
5
5
SW13
SW13
IP65, IP66K, IP67
IP65, IP66K, IP67
125 V
125 V
125 V
125 V
30 V
30 V
30 V
30 V
4 A
4 A
M12 x 1
M12 x 1
IP65, IP67, IP66K
IP65, IP67, IP66K
inserted, screwed
inserted, screwed
3
3
1,5 kV
1,5 kV
I
I
Nickeled
Nickeled
nickel plated
nickel plated
Zinc die-casting
Zinc die-casting
Zinc die-casting
Zinc die-casting
inserted, screwed, Shaking protection
inserted, screwed, Shaking protection
-25 °C
-25 °C
85 °C
85 °C
depending on cable quality
depending on cable quality
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
DIN EN 61076-2-101 (M12)
DIN EN 61076-2-101 (M12)
-
brown, black, blue, white, gray
732
732
3
3
-
-
black
black
cURus
cURus
-
-
-
-
1
1
5 wires around Core filler twisted
5 wires around Core filler twisted
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
yes
yes
brown, black, blue, white, gray
brown, black, blue, white, gray
-
-
41,8 g/m
41,8 g/m
PUR
PUR
90 ± 5 Shore A
90 ± 5 Shore A
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
4,8 mm
4,8 mm
± 5 %
± 5 %
PP
PP
5
5
1,25 mm
1,25 mm
± 5 %
± 5 %
70 ± 5 Shore D
70 ± 5 Shore D
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
42
42
0,1 mm
0,1 mm
0,34 mm²
0,34 mm²
Stranded copper wire, bare
Stranded copper wire, bare
strand class 6
strand class 6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
10 m @ 25 °C | horizontal
-
300 V
300 V
-
-
-
-
to DIN VDE 0298-4
to DIN VDE 0298-4
4,5 A
4,5 A
-
-
-
-
57 Ω/km @ 20 °C
57 Ω/km @ 20 °C
-
-
2,5 kV @ 60 s
2,5 kV @ 60 s
-
-
-
-
2,5 kV @ 60 s
2,5 kV @ 60 s
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-40 °C
-40 °C
80 °C / 90 °C @ 10000 h Operation
80 °C / 90 °C @ 10000 h Operation
-25 °C
-25 °C
80 °C / 90 °C @ 10000 h Operation
80 °C / 90 °C @ 10000 h Operation
-
-
-
-
-
-
-
-
DIN EN ISO 4892-2 A
DIN EN ISO 4892-2 A
UL 1581 § 1090 | UL 1581 § 1100 FT2 | IEC 60332-2-2
UL 1581 § 1090 | UL 1581 § 1100 FT2 | IEC 60332-2-2
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
DIN EN 60811-404 | Good, application-related testing
DIN EN 60811-404 | Good, application-related testing
5 x Outer diameter
5 x Outer diameter
10 x Outer diameter
10 x Outer diameter
-
10 Mio. @ 25 °C
-
10 m @ 25 °C | horizontal
10 Mio. @ 25 °C
3 m/s @ 25 °C
2 Mio.
2 Mio.
± 180 °/m
± 180 °/m
35 cycles/min
35 cycles/min
27279218
27279218
27279218
27279218
27279218
27279218
27060311
27060311
27060311
27060311
27060311
27060311
27060311
27060311
EC001855
EC001855
1
1
85444290
85444290
4048879181181
4048879181174
* plus VAT, plus shipping