Article |
|
Technical Data
|
Cable length:
|
Side 1 |
Tightening torque:
|
Coating contact:
|
Family construction form:
|
Thread:
|
Material contact:
|
Width across flats:
|
Electrical data | Supply |
Operating voltage AC max.:
|
Operating voltage DC max.:
|
Operating voltage AC max. (UL-listed):
|
Current operating per contact max.:
|
Device protection | Electrical |
Degree of protection (EN IEC 60529):
|
Additional condition protection degree:
|
Pollution Degree:
|
Rated surge voltage:
|
Material group (IEC 60664-1):
|
Mechanical data | Material data |
Coating housing:
|
Material housing:
|
Mechanical data | Mounting data |
Mounting method:
|
Environmental characteristics | Climatic |
Operating temperature min.:
|
Operating temperature max.:
|
Additional condition temperature range:
|
Important installation notes |
Note on strain relief:
|
Note on bending radius:
|
Cable data
|
General data | Cable |
Cable identification:
|
Jacket Color:
|
Type of Certificate:
|
Structure | Cable |
wire arrangement:
|
Mechanical data | Cable |
Material wire insulation:
|
Amount wires:
|
Outer diameter insulation :
|
Outer diameter tolerance core insulation:
|
Conductor crosssection (wire):
|
Temperature range | Cable |
Min. operating temperature (static):
|
Max. operating temperature (fixed):
|
Operating temperature min. (dynamic):
|
Operating temperature max. (dynamic):
|
Resistances | Cable |
Hydrolysis resistance:
|
Ozone resistance:
|
Seewater resistance:
|
Acid and alkali resistance:
|
UV resistance:
|
Flame resistance:
|
chemical resistance:
|
Gasoline resistance:
|
Oil resistance:
|
Installation | Cable |
Bending radius (fixed):
|
Classifications |
ECLASS-6.0:
|
ECLASS-6.1:
|
ECLASS-7.0:
|
ECLASS-8.0:
|
ECLASS-9.0:
|
ECLASS-10.1:
|
ECLASS-11.1:
|
ECLASS-12.0:
|
ETIM-5.0:
|
Commercial data |
GTIN:
|
customs tariff number:
|
Packaging unit:
|
|
|
|
|
|
|
|
0,2 m
|
0,2 m
|
|
|
1,5 Nm
|
1,5 Nm
|
gold plated
|
gold plated
|
7/8"
|
7/8"
|
7/8"
|
7/8"
|
Brass
|
Brass
|
SW24
|
SW24
|
|
|
300 V
|
600 V
|
-
|
600 V
|
600 V
|
-
|
7 A
|
6 A
|
|
|
IP68
|
IP68
|
inserted, screwed
|
inserted, screwed
|
3
|
-
|
4 kV
|
4 kV
|
III
|
III
|
|
|
nickel plated
|
nickel plated
|
Zinc die-casting
|
Zinc die-casting
|
|
|
inserted, screwed, Shaking protection
|
inserted, screwed, Shaking protection
|
|
|
-25 °C
|
-25 °C
|
85 °C
|
85 °C
|
depending on cable quality
|
depending on cable quality
|
|
|
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
|
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
|
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
|
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
|
|
|
|
|
977
|
978
|
-
|
-
|
-
|
-
|
|
|
brown, white, blue, black
|
brown, white, blue, black, green-yellow
|
|
|
PVC
|
PVC
|
4
|
5
|
-
|
3,1 mm
|
-
|
± 5 %
|
0,75 mm²
|
0,75 mm²
|
|
|
-
|
-25 °C
|
-
|
85 °C
|
-
|
-10 °C
|
-
|
50 °C
|
|
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
UL 1581 § 1090 | UL 1581 § 1100 FT2 | IEC 60332-2-2
|
IEC 60332-2-2 | UL 1581 § 1090 | UL 1581 § 1100 FT2
|
Good, application-related testing
|
Good, application-related testing
|
Good, application-related testing
|
Good, application-related testing
|
Good, application-related testing | DIN EN 60811-404
|
DIN EN 60811-404 | Good, application-related testing
|
|
|
-
|
10 x Outer diameter
|
|
|
27279218
|
27279218
|
27279220
|
27279220
|
27440103
|
27440103
|
27440103
|
27440103
|
27440103
|
27440103
|
27440103
|
27440103
|
27440103
|
27440103
|
27440103
|
27440103
|
EC001855
|
EC001855
|
|
|
4048879134651
|
4048879134644
|
85444290
|
85444290
|
1
|