Har du spørgsmål om vores produkter? Vores eksperter er klar til at hjælper dig! Ring til os +45 96 35 06 06

Produktsammenligning for 2 artikler

 Vidresend
Artikel
Tekniske specifikationer
Cable length:
Side 1
Tightening torque:
Mounting method:
Family construction form:
Thread:
Material:
Degree of protection (EN IEC 60529):
Electrical data
Capacity CX:
Electrical data | Supply
Operating voltage AC:
Operating voltage AC min.:
Operating voltage AC max.:
Operating voltage DC:
Operating voltage DC min.:
Operating voltage DC max.:
Cut-off peak voltage max.:
Current operating per contact max.:
Current consumption max.:
Diagnostics
Status indication LED:
Installation | Connection
Mounting set:
Device protection | Electrical
Additional condition protection degree:
Pollution Degree:
Rated surge voltage:
Material group (IEC 60664-1):
Additional suppressor:
Mechanical data | Material data
Coating locking:
Coating of fitting:
Color housing:
Material gasket:
Locking material:
Material screw connection:
Mechanical data | Mounting data
Mounting method:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Kabeldata
General data | Cable
Cable identification:
Cable Type:
Printing color of wire insulation:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
wire arrangement:
Mechanical data | Cable
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Ingredient freeness wire insulation:
Printing color of wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Conductor type (wire):
Traversing distance (C-track):
Travel speed (C-track):
Electrical data | Cable
Nominal voltage AC max.:
Current load capacity (standard):
Current load capacity min. wire:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Power frequency withstand voltage (wire - jacket):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (fixed):
Bending radius (dynamic):
Travel speed (C-track):
No. of torsion cycles:
Torsion stress:
Torsion speed:
Classifications
ECLASS-6.0:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Commercial data
GTIN:
customs tariff number:
Pakke-enhed:
Godkendelser
Certificates
Certificate
Certificate
Certificate
Certificate
Flyt artikel
MSUD valve plug A-18mm with cable MSUD valve plug A-18mm with cable
PUR 3x0.75 bk UL/CSA+drag ch. 1.5m
Vægt: 0.112 kg
Art. nr.: 7000-18021-6480150

ikke tilgængelig
Flyt artikel
MSUD valve plug A-18mm with cable MSUD valve plug A-18mm with cable
PUR 3x0.75 bk UL/CSA+drag ch. 1.5m
Vægt: 0.121 kg
Art. nr.: 7000-18021-6360150

Tilgængelig
1,5 m
1,5 m
0,4 Nm
0,4 Nm
inserted, screwed
inserted, screwed
MSUD A
MSUD A
M3
M3
PBT
PBT
IP67
IP67
20 ms
20 ms
24 V
24 V
19,2 V
19,2 V
28,8 V
28,8 V
24 V
24 V
18 V
18 V
30 V
30 V
55 V
55 V
4 A
4 A
15 mA
15 mA
yellow
yellow
M3
M3
inserted, screwed
inserted, screwed
3
3
0,8 kV
0,8 kV
I
I
Diode, Z-Diode
Diode, Z-Diode
verzinkt
verzinkt
verzinkt
verzinkt
black
black
PUR
PUR
Steel
Steel
Steel
Steel
inserted, screwed
inserted, screwed
-25 °C
-25 °C
85 °C
85 °C
depending on cable quality
depending on cable quality
-
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
-
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
648
636
3
3
white (isolation black)
white (isolation black)
black
black
cURus
cURus
1
1
3 wires twisted
3 wires twisted
black 1, black 2, green-yellow
black 1, black 2, green-yellow
54,45 g/m
56,1 g/m
PUR
PUR
90 ± 5 Shore A
90 ± 5 Shore A
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
6 mm
5,9 mm
± 5 %
± 5 %
PP
PP
3
3
1,98 mm
1,85 mm
± 5 %
± 5 %
65 ± 5 Shore D
70 ± 5 Shore D
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
white (isolation black)
white (isolation black)
42
42
0,15 mm
0,15 mm
0,75 mm²
0,75 mm²
Stranded copper wire, bare
Stranded copper wire, bare
strand class 6
strand class 6
5 m @ 25 °C | horizontal
10 m @ 25 °C | horizontal
5 Mio. @ 25 °C
-
600 V
300 V
to DIN VDE 0298-4
to DIN VDE 0298-4
12 A
12 A
26 Ω/km @ 20 °C
26 Ω/km @ 20 °C
6 kV @ 60 s
2,5 kV @ 60 s
6 kV @ 60 s
2,5 kV @ 60 s
-40 °C
-40 °C
90 °C
80 °C / 90 °C @ 10000 h Operation
-25 °C
-25 °C
90 °C
80 °C / 90 °C @ 10000 h Operation
-
-
-
-
-
-
-
-
DIN EN ISO 4892-2 A
DIN EN ISO 4892-2 A
UL 1581 § 1090 | UL 1581 § 1100 FT2 | IEC 60332-2-2
IEC 60332-2-2 | UL 1581 § 1100 FT2 | UL 1581 § 1090
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
DIN EN 60811-404 | Good, application-related testing
Good, application-related testing | DIN EN 60811-404
5 x Outer diameter
5 x Outer diameter
10 x Outer diameter
10 x Outer diameter
-
10 Mio. @ 25 °C
2 Mio.
2 Mio.
± 180 °/m
± 180 °/m
35 cycles/min
35 cycles/min
27279218
27279218
27279218
27279218
27279218
27279218
27060311
27060311
27060312
27060312
27060312
27060312
27060312
27060312
EC001855
EC001855
4048879647939
4048879193535
85444290
85444290
1
1
* Plus moms og forsendelsesomkostninger