Har du spørgsmål om vores produkter? Vores eksperter er klar til at hjælper dig! Ring til os +45 96 35 06 06

Produktsammenligning for 2 artikler

 Vidresend
Artikel
Tekniske specifikationer
Cable length:
Electrical data | Supply
Operating voltage AC min.:
Operating voltage AC max.:
Operating voltage DC min.:
Operating voltage DC max.:
Current operating per contact max.:
Current consumption max.:
Diagnostics
Status indication LED:
Device protection | Electrical
Degree of protection (EN IEC 60529):
Additional condition protection degree:
Rated surge voltage:
Device protection | Media
Flame resistance:
Mechanical data | Material data
Color housing:
Material housing:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Kabeldata
General data | Cable
Cable identification:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
wire arrangement:
Mechanical data | Cable
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Ingredient freeness wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Conductor type (wire):
Traversing distance (C-track):
Electrical data | Cable
Max. rated voltage (conductor - conductor):
Max. rated voltage (conductor - ground):
Current load capacity (standard):
Current load capacity min. wire:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Power frequency withstand voltage (wire - jacket):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (dynamic):
Travel speed (C-track):
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Commercial data
Pakke-enhed:
GTIN:
customs tariff number:
Flyt artikel
Valve plug MJC 90° with cable LED Valve plug MJC 90° with cable LED
PUR 2x0.5 bk drag ch. 10m
Vægt: 0.324 kg
Art. nr.: 7000-70321-7401000

Kontakt os for leveringsdato
Flyt artikel
Valve plug MJC 0° with cable LED Valve plug MJC 0° with cable LED
PUR 2x0.5 bk drag ch. 10m
Vægt: 0.325 kg
Art. nr.: 7000-70021-7401000

Tilgængelig
10 m
10 m
10 V
10 V
30 V
30 V
10 V
10 V
30 V
30 V
4 A
4 A
12 mA
12 mA
yellow
yellow
IP65
IP65
inserted, locked
inserted, locked
0,8 kV
0,8 kV
flame retardant
flame retardant
black
black
Plastic
Plastic
-25 °C
-25 °C
85 °C
85 °C
depending on cable quality
depending on cable quality
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
740
740
black
black
-
-
1
1
2 wires twisted
2 wires twisted
black, white
black, white
36,3 g/m
36,3 g/m
PUR
PUR
85 Shore A
85 Shore A
lead-free, cadmium-free, CFC-free, halogen-free
lead-free, cadmium-free, CFC-free, halogen-free
5 mm
5 mm
± 5 %
± 5 %
TPE-E
TPE-E
2
2
1,5 mm
1,5 mm
± 5 %
± 5 %
70 Shore A
70 Shore A
lead-free, CFC-free, halogen-free
lead-free, CFC-free, halogen-free
64
64
0,1 mm
0,1 mm
0,5 mm²
0,5 mm²
Stranded copper wire, bare
Stranded copper wire, bare
strand class 6
strand class 6
5 m @ 25 °C | horizontal
5 m @ 25 °C | horizontal
500 V
500 V
300 V
300 V
to DIN VDE 0298-4
to DIN VDE 0298-4
9 A
9 A
39 Ω/km @ 20 °C
39 Ω/km @ 20 °C
2 kV @ 60 s
2 kV @ 60 s
2 kV @ 60 s
2 kV @ 60 s
-50 °C
-50 °C
90 °C
90 °C
-30 °C
-30 °C
90 °C
90 °C
-
-
-
-
-
-
-
-
DIN EN ISO 4892-2 A
DIN EN ISO 4892-2 A
UL 1581 § 1100 FT2 | UL 1581 § 1090 | IEC 60332-2-2
UL 1581 § 1100 FT2 | UL 1581 § 1090 | IEC 60332-2-2
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing | DIN EN 60811-404
Good, application-related testing | DIN EN 60811-404
10 x Outer diameter
10 x Outer diameter
2 Mio. @ 25 °C
2 Mio. @ 25 °C
27279218
27279218
27279218
27279218
27279218
27279218
27279218
27279218
27060312
27060312
27060312
27060312
27060312
27060312
27060312
27060312
EC001855
EC001855
1
1
4048879286138
4048879135597
85444290
85444290
* Plus moms og forsendelsesomkostninger