Valve plug MDC06-4s with cable
PUR / PVC 2x1.5+1x2x0.5 bk 3m
Art. nr.: | 7072-72165-2600300 |
Vægt: | 0.332 kg |
Country of origin: | DE |
Kontakt os for leveringsdato
Beskrivelse
Xtreme - Outdoor
Xtreme - Outdoor
Male straight
Male straight
The resistance to aggressive media should be individually tested for your application. Further details on request.
The resistance to aggressive media should be individually tested for your application. Further details on request.
Further cable lengths on request.
Further cable lengths on request.
6 ... 32 V AC/DC
6 ... 32 V AC/DC
4-pole
4-pole
Shielded
Shielded
without components
without components
without cable sleeves
without cable sleeves
Compatible with:
Compatible with:
Deutsch DT06-4S
Deutsch DT06-4S
Plastic housings with good resistance against chemicals and oils.
Plastic housings with good resistance against chemicals and oils.
Tekniske specifikationer
Cable length | 3 m |
---|---|
Cable length | 3 m |
Side 1
Mounting method | inserted |
---|---|
Mounting method | inserted |
Coating contact | nickel plated |
Coating contact | nickel plated |
Family construction form | MDC |
Family construction form | MDC |
suitable for corrugated tube (internal Ø) | 13 mm |
suitable for corrugated tube (internal Ø) | 13 mm |
Material contact | Copper alloy |
Material contact | Copper alloy |
No. of poles | 4 |
No. of poles | 4 |
Side 2
Stripping length (jacket) | 40 mm |
---|---|
Stripping length (jacket) | 40 mm |
Electrical data | Supply
Operating voltage AC min. | 6 V |
---|---|
Operating voltage AC min. | 6 V |
Operating voltage AC max. | 32 V |
Operating voltage AC max. | 32 V |
Operating voltage DC min. | 6 V |
Operating voltage DC min. | 6 V |
Operating voltage DC max. | 32 V |
Operating voltage DC max. | 32 V |
Current operating per contact max. | 4 A |
Current operating per contact max. | 4 A |
Diagnostics
Status indication LED | no |
---|---|
Status indication LED | no |
Installation | Connection
Stripping length (jacket) | 40 mm |
---|---|
Stripping length (jacket) | 40 mm |
Family construction form | Amphenol AT06-4S |
Family construction form | Amphenol AT06-4S |
Device protection | Electrical
Degree of protection (ISO 20653:2013) | IP66K, IP68, IP69K |
---|---|
Degree of protection (ISO 20653:2013) | IP66K, IP68, IP69K |
Pollution Degree | 2 |
Pollution Degree | 2 |
Rated surge voltage | 0,8 kV |
Rated surge voltage | 0,8 kV |
Material group (IEC 60664-1) | III |
Material group (IEC 60664-1) | III |
Additional suppressor | without components |
Additional suppressor | without components |
Mechanical data | Material data
Material gasket | Silicon |
---|---|
Material gasket | Silicon |
Material housing | PA |
Material housing | PA |
Mechanical data | Mounting data
Looking techniques | Snap-in connector |
---|---|
Looking techniques | Snap-in connector |
Environmental characteristics | Climatic
Operating temperature min. | -25 °C |
---|---|
Operating temperature min. | -25 °C |
Operating temperature max. | 85 °C |
Operating temperature max. | 85 °C |
Additional condition temperature range | depending on cable quality |
Additional condition temperature range | depending on cable quality |
Important installation notes
Note on strain relief | Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties. |
---|---|
Note on strain relief | Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties. |
Note on bending radius | Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces. |
Note on bending radius | Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces. |
Kabeldata
General data | Cable
Cable identification | 260 |
---|---|
Cable identification | 260 |
Jacket Color | yellow |
Jacket Color | yellow |
Structure | Cable
Amount stranding | 1 |
---|---|
Amount stranding | 1 |
Stranding | 2 wires twisted |
Stranding | 2 wires twisted |
Amount stranding (type 2) | 1 |
Amount stranding (type 2) | 1 |
Stranding (type 2) | 2 wires with Stranding combination twisted |
Stranding (type 2) | 2 wires with Stranding combination twisted |
Filler | yes |
Filler | yes |
wire arrangement | brown, blue, gray, pink, white, black |
wire arrangement | brown, blue, gray, pink, white, black |
Mechanical data | Cable
Cable weigth | 99 g/m |
---|---|
Cable weigth | 99 g/m |
Material jacket | PUR |
Material jacket | PUR |
Freedom from ingredients (jacket) | lead-free, cadmium-free, CFC-free |
Freedom from ingredients (jacket) | lead-free, cadmium-free, CFC-free |
Outer-diameter (jacket) | 8,8 mm |
Outer-diameter (jacket) | 8,8 mm |
Tolerance outer diameter (sheath) | ± 5 % |
Tolerance outer diameter (sheath) | ± 5 % |
Material inner jacket | PVC |
Material inner jacket | PVC |
Color (inner jacket) | black |
Color (inner jacket) | black |
Material wire insulation | PVC |
Material wire insulation | PVC |
Amount wires | 2 |
Amount wires | 2 |
Outer diameter insulation | 2,25 mm |
Outer diameter insulation | 2,25 mm |
Outer diameter tolerance core insulation | ± 5 % |
Outer diameter tolerance core insulation | ± 5 % |
Ingredient freeness wire insulation | lead-free, CFC-free |
Ingredient freeness wire insulation | lead-free, CFC-free |
Amount strands (wire) | 84 |
Amount strands (wire) | 84 |
Diameter of single wires | 0,15 mm |
Diameter of single wires | 0,15 mm |
Conductor crosssection (wire) | 1,5 mm² |
Conductor crosssection (wire) | 1,5 mm² |
Material conductor wire | Stranded copper wire, bare |
Material conductor wire | Stranded copper wire, bare |
Conductor type (wire) | strand class 6 |
Conductor type (wire) | strand class 6 |
Material wire insulation (Data) | PP |
Material wire insulation (Data) | PP |
Outer diameter wire insulation (Data) | 2 mm |
Outer diameter wire insulation (Data) | 2 mm |
Tolerance outer diameter wire insulation (data) | ± 5 % |
Tolerance outer diameter wire insulation (data) | ± 5 % |
Ingredient freeness wire insulation (Data) | lead-free, CFC-free, halogen-free |
Ingredient freeness wire insulation (Data) | lead-free, CFC-free, halogen-free |
Amount wires (Data) | 2 |
Amount wires (Data) | 2 |
Amount strands wire (Data) | 16 |
Amount strands wire (Data) | 16 |
Diameter of single wires (Data) | 0,2 mm |
Diameter of single wires (Data) | 0,2 mm |
Conductor crosssection wire (Data) | 0,5 mm² |
Conductor crosssection wire (Data) | 0,5 mm² |
Material conductor wire (Data) | Stranded copper wire, bare |
Material conductor wire (Data) | Stranded copper wire, bare |
Wire conductor type (Data) | Strand class 5 |
Wire conductor type (Data) | Strand class 5 |
No. of bending cycles (C-track) | 5 Mio. |
No. of bending cycles (C-track) | 5 Mio. |
Traversing distance (C-track) | 5 m | horizontal |
Traversing distance (C-track) | 5 m | horizontal |
Travel speed (C-track) | 3,3 m/s |
Travel speed (C-track) | 3,3 m/s |
Electrical data | Cable
Nominal voltage AC max. | 60 V |
---|---|
Nominal voltage AC max. | 60 V |
Current load capacity (standard) | to DIN VDE 0298-4 |
Current load capacity (standard) | to DIN VDE 0298-4 |
Current load capacity min. wire | 14,4 A |
Current load capacity min. wire | 14,4 A |
Current load capacity min. Wire (Data) | 7,2 A |
Current load capacity min. Wire (Data) | 7,2 A |
Electrical resistance line constant wire | 13,3 Ω/km @ 20 °C |
Electrical resistance line constant wire | 13,3 Ω/km @ 20 °C |
Electrical resistance coating wire (Data) | 40,1 Ω/km |
Electrical resistance coating wire (Data) | 40,1 Ω/km |
AC withstand voltage (wire - wire) | 1 kV @ 60 s |
AC withstand voltage (wire - wire) | 1 kV @ 60 s |
Temperature range | Cable
Min. operating temperature (static) | -40 °C |
---|---|
Min. operating temperature (static) | -40 °C |
Max. operating temperature (fixed) | 80 °C |
Max. operating temperature (fixed) | 80 °C |
Operating temperature min. (dynamic) | -5 °C |
Operating temperature min. (dynamic) | -5 °C |
Operating temperature max. (dynamic) | 80 °C |
Operating temperature max. (dynamic) | 80 °C |
Resistances | Cable
Flame resistance | IEC 60332-2-2 | UL 1581 § 1100 FT2 | UL 1581 § 1090 |
---|---|
Flame resistance | IEC 60332-2-2 | UL 1581 § 1100 FT2 | UL 1581 § 1090 |
chemical resistance | Good, application-related testing |
chemical resistance | Good, application-related testing |
Gasoline resistance | Good, application-related testing |
Gasoline resistance | Good, application-related testing |
Oil resistance | DIN EN 60811-404 | Good, application-related testing |
Oil resistance | DIN EN 60811-404 | Good, application-related testing |
Installation | Cable
Bending radius (installation) | x Outer diameter |
---|---|
Bending radius (installation) | x Outer diameter |
Bending radius (fixed) | x Outer diameter |
Bending radius (fixed) | x Outer diameter |
Bending radius (dynamic) | 10 x Outer diameter |
Bending radius (dynamic) | 10 x Outer diameter |
No. of torsion cycles | Mio. |
No. of torsion cycles | Mio. |
Torsion speed | cycles/min |
Torsion speed | cycles/min |
Commercial data
ECLASS-6.0 | 27279218 |
---|---|
ECLASS-6.0 | 27279218 |
ECLASS-6.1 | 27279218 |
ECLASS-6.1 | 27279218 |
ECLASS-7.0 | 27279218 |
ECLASS-7.0 | 27279218 |
ECLASS-8.0 | 27279218 |
ECLASS-8.0 | 27279218 |
ECLASS-9.0 | 27060312 |
ECLASS-9.0 | 27060312 |
ECLASS-10.1 | 27060312 |
ECLASS-10.1 | 27060312 |
ECLASS-11.1 | 27060312 |
ECLASS-11.1 | 27060312 |
ECLASS-12.0 | 27060312 |
ECLASS-12.0 | 27060312 |
ETIM-5.0 | EC001855 |
ETIM-5.0 | EC001855 |
customs tariff number | 85444290 |
GTIN | 4065909056691 |
Pakke-enhed | 1 |